Spherical Third-generation Night Vision Image Intensifier

Spherical Third-generation Night Vision Image Intensifier

Features: Inverted Image Output, Spherical Output Surface

This type of third-generation low-light image intensifier adopts a light-shielding glass with anti-halo blackening as the input window and a fiber optic inverter as the output window. The output surface is SR40mm concave spherical, and the output image is inverted by 180° compared to the input image.

Spherical Third-generation Night Vision Image Intensifier

Mainly used in direct-view low-light night vision devices. The performance is graded as follows:
Performance Parameters 04 05 06 07 08 09
Resolution lp/mm Ultimate Resolution 51 55 61 64 64 64
High Light Resolution
(@100lx)
5 5 5 5 5 5

Sensitivity

2856K Light Sensitivity
1600 1600 1800 1800 2000 2000

880 Radiant Sensitivity
90 90 95 95 95 95
Signal-to - Noise Ratio (SNR) 25 28 28 28 28 30
Lumi nance Gain( cd/m2/ lx 8000-20000 11000-20000 11000-20000 11000-20000 12000-25000 12000-25000
Equivalent Background Illumi nance( × 10-7 lx) 2.5 2.5 2.5 2.5 2.5 2.5
Output Lumi nance (cd/m2@ 1lx~ 10lx) 4-8 4-8 4- 12 4- 12 4- 12 6- 12
Lumi nance Uniformity(@2856K 3:1 3:1 3:1 3:1 3:1 3:1

MTF
2 .5lp/ mm 88% 88% 88% 89% 89% 89%
7 .5lp/ mm 68% 70% 72% 74% 74% 74%
15lp/ mm 42% 46% 54% 60% 60% 60%
25lp/ mm 22% 25% 30% 35% 35% 35%
Working Lifetime (h) 7500 7500 7500 10000 10000 10000
Operating Voltage  V 2.2-3.4 2.2-3.4 2.2-3.4 2.2-3.4 2.2-3.4 2.2-3.4
Weight g 80 80 80 80 80 80
Compact High-Voltage Power Supply DC High-Voltage  Power Supply or Automatic Door Control Power Supply
Effective Cathode Diameter( mm Not Less Than 17.5
Electrical Connection End Leads
Fluorescent Screen Type P43 or P45


Note: When selecting the optional automatic door control compact high-voltage power supply, this specification should be not less than 32 lp/mm.
 


视场清洁度分级
暗点尺寸
μm
H S
Ⅰ区 Ⅱ区 Ⅲ区 Ⅰ区 Ⅱ区 Ⅲ区
381 0 0 0 0 0 0
305  381 0 1 1 0 0 0
229  305 0 1 2 0 0 0
152 229 1 2 3 0 1 1
76 152 3 4 5 0 2 2

Note: For details on field zoning and dark point specifications, please refer to the overview page on field cleanliness. Performance grades and field cleanliness grades can be combined and matched

Contact Us